Design Methane Pressure (Soil Formation Pressure): under the Los Angeles Department of Building and Safety (LADBS) Methane Code, Ordinance No. 175790, the highest soil gas pressure measured at a site during methane testing. It is also called soil formation pressure and is reported in inches of water column.
How It Is Measured
Pressure is measured at the soil gas probes, usually with a sensitive gauge, at the same time as methane concentration. The highest pressure recorded at the site becomes the design methane pressure.
Why Pressure Matters
Gas under pressure is pushed toward areas of lower pressure, such as the inside of a building. A high soil gas pressure means methane can move more forcefully through cracks, utility penetrations and joints in a slab.
Site Design Level
Together with the design methane concentration, the design methane pressure sets the project’s site design level, from Level I through Level V. The site design level determines the required methane mitigation system.
Mitigation Response
Higher pressures can require more robust venting, a stronger impervious membrane, vent risers, trench dams and active systems such as mechanical ventilation and gas detectors.
Frequently Asked Questions
What units is design methane pressure in?
Inches of water column.
Is soil formation pressure the same as design methane pressure?
Yes. LADBS uses both terms.
Related Terms
- Design Methane Concentration
- Methane Soil Gas
- Vent Riser in Methane Mitigation
- Trench Dam
- De-watering System
Building in a methane zone? Call (888) 930-6604 to talk with a Geo Forward geologist.
Sources
- Los Angeles Department of Building and Safety: Methane Mitigation Standards
- California Geologic Energy Management Division: Oil and Gas
- California Geological Survey
Technical Review
Reviewed by Adam Azad Kaligi, PG
Founder and Licensed Professional Geologist, Geo Forward, Inc.
Last updated: November 2026





